Search results for "Skin surface"
showing 10 items of 18 documents
Physical and chemical properties of skin in habitually trained and sedentary men.
1978
A number of physical and chemical properties of skin were examined in a study of 29 habitually trained and 29 sedentary men. Compared to the control group, the trained subjects had significantly higher values in the weights of skin samples of equal surface areas as well as the contents of hydroxyproline and nitrogen per skin surface area. When measured by a diaphragm method in vivo, the 'elastic stiffness' (uncorrected for thickness) and 'elastic efficiency' (the recovery of the deformation energy) of skin were significantly higher in the trained men compared to those in the untrained men. The results suggest that skin reflects the adaptation to habitual endurance training by increasing its…
Responsiveness of human neonates to the odor of 5alpha-androst-16-en-3-one: A behavioral paradox?
2014
The odorous steroid 5alpha-androst-16-en-3-one (AND) occurs in numerous biological fluids in mammals, including man, where it is believed to play a chemocommunicative role. As AND was recently detected in milk and amniotic fluid, sensitivity and hedonic responses to this substance were assessed in human neonates. To this aim, respiration and facial expressions were recorded in 3-day-old newborns in response to aqueous solutions of AND, ranging from 500ng/mL to 0.5 fg/mL. Although analyses of respiratory rate did not lead to clear-cut results, the newborns changed their facial expressions at concentrations not detected by adults in a triangle test. Newborns displayed negative facial actions …
A ballistometer for the study of the plasto-elastic properties of skin.
1977
The ballistrometer is based on the "drop impact" of a body onto a stationary surface. A collision in one dimension is provoked by allowing a bard body to drop from a given height onto the skin surface to be tested. After the collision, the impacting body undergoes a variable number of rebounds decreasing in amplitude. By measuring the height of the rebounds, the amount of energy returned by the tissue is calculated in terms of coefficient of restitution e. The equipment, consisting of a hammer unit, a feeder-amplifier, and a plotter, is described. Ballistometry has been carried out on skin areas of 46 normal subjects ranging in age from 8 to 80 years, as well as on pathologic and cadaveric …
Multimodal device for assessment of skin malformations
2013
A variety of multi-spectral imaging devices is commercially available and used for skin diagnostics and monitoring; however, an alternative cost-efficient device can provide an advanced spectral analysis of skin. A compact multimodal device for diagnosis of pigmented skin lesions was developed and tested. A polarized LED light source illuminates the skin surface at four different wavelengths – blue (450 nm), green (545 nm), red (660 nm) and infrared (940 nm). Spectra of reflected light from the 25 mm wide skin spot are imaged by a CMOS sensor. Four spectral images are obtained for mapping of the main skin chromophores. The specific chromophore distribution differences between different skin…
Treatment of Dimpling from Cellulite.
2018
Background:. Cellulite can be seen on the skin in widespread alterations of the skin surface and dimpling. The purpose of this study was to assess the effectiveness and safety of the manual subcision technique to treat dimpling from cellulite, using a specific class IIA medical device (Celluerase). Methods:. The multi-center observational study assessed 200 women treated in a single session for different dimpling, using manual subcision administered by Celluerase. Aesthetic outcomes were evaluated by the authors, and the patients assessed satisfaction levels. Results:. Two hundred women between 20 and 55 years were treated. The medical evaluation of patients saw improvements with an average…
Perspiration versus saliva--basic aspects concerning their use in roadside drug testing.
1999
Various aspects concerning the practical application and forensic interpretation of data obtained by saliva drug testing and drug monitoring from the skin surface are discussed. Basic information on the composition of saliva and skin secretions and their particular transport mechanisms, as far as known, are given. For drugs of abuse secretion into saliva is suggested to be by passive diffusion and to depend on lipid solubility, pKa, plasma protein binding and on the pH of saliva. Drug molecules from blood are considered to reach the skin surface by various routes such as by sweat and sebum as well as by inter- and/or transcellular diffusion. The role of the stratum corneum as a temporary dr…
Thermal imaging ruled out as a supplementary assessment in patients with fibromyalgia: A cross-sectional study
2021
Background The diagnosis of fibromyalgia syndrome (FMS) syndrome is often complicated and relies on diagnostic criteria based mostly on the symptoms reported by patients. Implementing objective complementary tests would be desirable to better characterize this population. Objective The purpose of this cross-sectional study was to compare the skin temperature at rest using thermography in women with FMS and healthy women. Methods Eighty-six women with FMS and 92 healthy controls volunteered to participate. The temperature of all participants was measured by infra-red thermography, registering the skin surface temperature (minimum, maximum and average) at rest in different areas: neck, upper…
Minimally invasive superficial temporal artery to middle cerebral artery bypass through a minicraniotomy: benefit of three-dimensional virtual realit…
2009
Object The aim of the authors in this study was to introduce a minimally invasive superficial temporal artery to middle cerebral artery (STA-MCA) bypass surgery by the preselection of appropriate donor and recipient branches in a 3D virtual reality setting based on 3-T MR angiography data. Methods An STA-MCA anastomosis was performed in each of 5 patients. Before surgery, 3-T MR imaging was performed with 3D magnetization-prepared rapid acquisition gradient echo sequences, and a high-resolution CT 3D dataset was obtained. Image fusion and the construction of a 3D virtual reality model of each patient were completed. Results In the 3D virtual reality setting, the skin surface, skull surface…
Simultaneous recording of skin blood pulsations at different vascular depths by multiwavelength photoplethysmography.
2007
A new technique for parallel recording of reflection photoplethysmography (PPG) signals in a broad spectral band (violet to near-infrared) has been developed, and its potential for assessment of blood microcirculation at various depths from the skin surface is discussed. PPG signals have been simultaneously detected at cw laser wavelength sets comprising 405, 532, 645, 807, and 1064 nm. Various signal baseline responses to breath holding and different shapes of the PPG pulses originated from the same heartbeat but recorded at different wavelengths have been observed, indicating a depth variety of the skin blood pulsation dynamics.
Multi-spectral Reflection Photoplethysmography: Potential for Skin Microcirculation Assessment
2006
Technique for simultaneous recording of reflection photoplethysmography signals in broad spectral band (violet to NIR) has been developed, and its potential for assessment of blood microcirculation at various depths from the skin surface is discussed.